stadium-lighting-fixtures-arrangement

Stadium lighting fixtures arrangement

35 Published by admin 06 21,2019

Relationship between lighting fixtures and sports and venues

 
The layout of the lighting should take into account the characteristics of the sports and the characteristics of the playing field.
Different sports will be carried out on different sizes and shapes of sports venues, and the sports venues will be used in different ways. The range of activities of athletes and the range of coverage in sports are also different. Stadium lighting fixtures should serve these sports to meet their needs. Therefore, the lamps are reasonably arranged on the basis of comprehensive consideration of the characteristics of the sports items and the characteristics of the sports grounds to obtain a good lighting level and avoid adverse effects on athletes and television broadcasts.

Lighting arrangement and glare and interference light

 
(1) Specification requirements. The installation position, height and projection angle of the luminaire should meet the requirements of reducing glare and controlling the interference light.
(2) About glare. The installation position, height and projection angle of the luminaire should meet the requirements of reducing glare and controlling the interference light.
In the lighting design of stadiums, glare and disturbance light are the primary unfavorable factors affecting athletes' competitive level, and also an important factor affecting the quality of TV broadcast.
Outdoor stadium: GR ≤ 50
GR ≤ 40 (fixed camera direction)
Indoor gymnasium: GR ≤ 30
(3) About interference light. Interference light is a kind of glare. It refers to the spill light that causes people's troubles, discomfort, distraction, or decreased visual ability due to the intensity, direction, or spectrum of light in a specific situation.
China's standards and CE standards put forward corresponding requirements for limiting interference light pollution, that is, divided into four areas from E1 to E4, see Table 1.

Area Characteristics Example
E1 area Natural dark area National parks and nature reserves
E2 area Low brightness area Rural industrial area and residential area
E3 area Medium brightness area Suburban industrial area and residential area
E4 area High brightness area City center and business area

 
Civil buildings around the stadium should not be subject to more interference. The vertical illumination produced on the outer surfaces of buildings such as houses, apartments, hotels and hospital wards should not exceed the values specified in Table 2.

Application Area (lx)
E1 area E2 area E3 area E4 area
Vertical illumination Before the light-off period 2 5 10 25
After the light-off period 0 1 2 5

 
The luminous intensity of stadium lighting towards the living room (including residential, apartment, hotel and hospital ward buildings, etc.) should be less than or equal to the value specified in Table 3.

Application Area (cd)
E1 area E2 area E3 area E4 area
Luminous intensity Before the light-off period 2500cd 7500cd 10000cd 25000cd
After the light-off period 0cd 500cd 1000cd 2500cd

 
Table 2 and Table 3 are also applicable to outdoor tennis, hockey, rugby, baseball, softball, beach volleyball, etc., especially pay attention to the lighting stadium in the community. Because the stadium is close to the house, the interference light may be small.
 

Vertical illumination and uniformity of light

The lighting arrangement for the venue where the TV broadcast is to be played shall meet the requirements for vertical illumination and uniformity of the main camera and the auxiliary camera.

Application of Mecree LED Lighting in airport