Product

Table of Contents
GL-SPL each detail aim to bring professional lighting experience for player and spectator. We wanted to create an LED lighting system that was bright, efficient, and maintenance-free, but still affordable. So we engineered a fixture that is small and lightweight enough to be mounted on your existing infrastructure, saving you a bundle on materials and labor.

Ultimate 1 to 2 replacement for 2kW HID
Glare free & No light pollution from Narrow beam reflector
Flicker free proven upto 1,500 fps ultra slow-motion
High CRI &R9 Content better visibility
Tilt and rotate for easy aiming
Linkage with wired control system even for event light control
Sports stadiums, football field, cricket stadium, baseball field, and long distance lighting.
| Model | Power | *Luminous Efficacy | *Luminous Flux | Color Temperature | CRI |
| GL-SPL-800W | 800W | 140 lm/W 145 lm/W 150 lm/W |
112,000 lm 116,000 lm 120,000 lm |
4000K/5000K/5700K/6500K | 90 Ra 80 Ra 70 Ra |
| GL-SPL-1000W | 1000W | 140,000 lm 145,000 lm 150,000 lm |
4000K/5000K/5700K/6500K | ||
| GL-SPL-1200W | 1200W | 168,000 lm 174,000 lm 180,000 lm |
4000K/5000K/5700K/6500K |

Customized superconducting heat dissipation system will easier bring out the heat on the COB board under air convection. Make sure ultra-low light decay 5% within 10 years and maintains constant 70˚C internal temperature.


We adapt High-quality and Durable raw material to ensure the user have no maintenance during several decades years. The whole lighting system is IP66 and suitable for outdoor special sites.

GL-SPL researched the newest unique secondary optical design. That Customized optics direct light onto the field and minimize glare from shining into the eyes of athletes. Athletes can see the action with our lights. Our single, glass optic lights every playing surface evenly with smooth, clear light.
LIGHT SPILL -10%
The LED system delivers unparalleled quality, controlling the light with pinpoint precision without creating glare or off-site spill, reducing light waste and complaints from the neighbors.

MECREE secondary optical are Aluminum Optical Reflective Cup+ Secondary Calculus Optical Lenses and High permeability reinforced tempered glass protection. Aim to minimize the spill light and glare and he linear light is used many times to effectively reduce the residual light and enhance the central light intensity more than 5 times. Improving the uniformity 10% on the field and suitable for 8K HD broadcasting.

Less power required with MECREE stadium lights, saving more than 70% energy compared with metal halide lamps.
Highly efficiency GL-SPL fixtures provide more LUX of light on the surface relative to the fixture count of the system. This all saves you a bundle on energy costs.

1-for-1 replacement for traditional stadium lamps (PHILIPS: MVF024, MVH-401/403/406 Arena Vision, MVF408-CAT1-1800W, NHF003; THORN: Mundial) on the existing infrastructure. This eliminates the expenses for new poles, crossarms, demolition, engineering, and foundations.

Just one tool free adjustment. Easily loosen, tighten and rotate the mounting bracket by hand. Saving the time and energy to the maximum extent.


MECREE GL-SPL Stadium Lights don’t use bulbs. So you save a lot of time and money over replacements needed with metal halide. Durable lighting system is better for your budget and slashing your operating costs.

GL-SPL is designed to be small, light, weather-proof and aerodynamic, taking weight off your existing poles and better withstanding the elements.

GL-SPL-RGB’s full-color LED fixtures create a dynamic lighting experience for sport match. Bring all spectator an amazing color lighting effect.

MECREE INTEGRATED POWER SUPPLY
MECREE’ smaller power supply is integrated within the fixture, providing a host of advantages: It reduces overall fixture weight, it draws less than 1% power while turned off, and it allows for more efficient operation while minimizing electromagentic interference. Our power supplies are also engineered to dissipate heat efficiently, greatly extending the system’s life.
REMOTE
Our competitors still cling to remote power supplies, which are proven to be incredibly inefficient. Their standby power draw is far higher than our solution. Their power supply also lacks modern thermal-management design, leading to frequent repairs and a reduced lifespan. They also introduce more electrical interference into the venue.

MECREE are committed to offer the right solution for every sport field including to football, baseball, cricket, hockey and professional stadium.
MECREE SPECIFICALLY DESIGNED PLC (PRECISE LIGHT CONTROL) TO MEET THE NEEDS OF SUCH USERS, POLARIZED LIGHT 73°DEFINED AS P73 SERIES PRODUCTS, P73 SERIES PRODUCTS TO BRING YOU AN UNPRECEDENTED VISUAL FEAST.
MECREE are not only a manufacturer of high-power LEDs, More professional services are also included:
1. According to the requirement to provide the best stadium lighting solutions, including horizontal, vertical illumination, uniformity, glare control, spill light control, energy saving.
2. About the design of lighting mast, Mecree according to the wind speed at the place can be used to calculate the axial force, bending force, horizontal shear force and torque for the construction engineer, so as to protect the users from unnecessary accidental.
3. One stop service for you! High power generator set supporting, and we also supply cables, switches, power distribution cabinet and other parts. We are your best supply chain manager!
4. Professional Lighting installation guide including to the circuit design service and installation angle guide of each lights.
Join MECREE! Save you time,unnecessary costs and greater benefits.

Why choose MECREE Lighting for your Cricket Field?