Product
Table of Contents
Natatorium lights are indoor pool lights mounted from above that provides lighting to the pool area. LED Natatorium lights are LED versions of the same named Metal Halide fixtures.

The natatorium lighting design usually considers the repair and maintenance of the lamps. Generally, they are not arranged above the surface of the lamps, but are provided with special maintenance channels above the water surface. For stadiums that do not have TV broadcasting requirements, lamps are often scattered on the water, the roof or the ceiling above the wall for decoration.
For sports venues with TV broadcasts, the lamps are generally decorated with light strips, that is, to decorate the crosswalk above the pool banks on both sides; in addition, it is necessary to install an appropriate number of lamps under the diving platform and springboard to eliminate the formation of jumping platforms and springboards. Shadows and provide key lighting for the warm-up pool for diving sports.

This depends on the level of competition of your field. Below are some lighting guide you can use to determine how many you need.
Professional: Pool: 750lux, Deck: 500lux
College: Pool: 500 lux, Deck: 200lux
Recreational: Pool 30lux, Deck: 10lux
It should be emphasized that natatorium lighting should not be set on the upper part of the diving pool for diving sports, otherwise the mirror image of the lighting will appear in the water, which will cause light interference to the athletes and affect the judgment and competition ability of the athletes. Therefore, no matter it is diving training or official competition, this kind of lighting should not be used.
BS EN 15288-1 Swimming Pool-Safety Requirements for Design is the European standard for safety design requirements for swimming pools. It contains recommendations on lighting levels.
It is recommended to maximize the use of natural light. Circulation, machine room and dressing area need a uniform 100 Lux. The water area needs a uniform 200 Lux. Allow lower levels, but strengthen supervision

The first task of natatorium lighting is to create a safe environment. In order to create such a safe environment, we should pay attention to the selection and placement of lamps.

The swimming pool receives natural light through windows and artificial light through lamps. Sometimes, the swimming pool is only illuminated by natural light, sometimes by artificial light. Sometimes it can be illuminated by a combination of the two. Another important natatorium lighting controls is dimmer, such as DMX, DALI, 0-10V.

Generally, a light level of 300 lux in a natatorium is sufficient. During the game; may require a lighting level of 500 lux or higher.
![]() |
Request Pricing Contractor / Bulk Pricing |
| Model: P73 Series | |
| Watts: 420W – 1260W | |
| Lead time: Sample in stock/bulk order depend on quantities | |
| Color temperature: 3000K/4000K/5000K/5700K/6500K | |
![]() |
Request Pricing Contractor / Bulk Pricing |
| Model: AFL-300W | |
| Watts: 300W | |
| Lead time: Sample in stock/bulk order depend on quantities | |
| Color temperature: 3000K/4000K/5000K/5700K/6500K | |
![]() |
Request Pricing Contractor / Bulk Pricing |
| Model: AFL-600W | |
| Watts: 600W | |
| Lead time:Sample in stock/bulk order depend on quantities | |
| Color temperature: 3000K/4000K/5000K/5700K/6500K | |
![]() |
Request Pricing Contractor / Bulk Pricing |
| Model: AFL-1000W | |
| Watts: 1000W | |
| Lead time:Sample in stock/bulk order depend on quantities | |
| Color temperature: 3000K/4000K/5000K/5700K/6500K | |
![]() |
Request Pricing Contractor / Bulk Pricing |
| Model: AFL-1200W | |
| Watts: 1200W | |
| Lead time:Sample in stock/bulk order depend on quantities | |
| Color temperature: 3000K/4000K/5000K/5700K/6500K | |
![]() |
Request Pricing Contractor / Bulk Pricing |
| Model: GL-SPL-1000W | |
| Watts: 1000W | |
| Lead time:Sample in stock/bulk order depend on quantities | |
| Color temperature: 3000K/4000K/5000K/5700K/6500K | |
![]() |
Request Pricing Contractor / Bulk Pricing |
| Model: GL-SPL-1200W | |
| Watts: 1200W | |
| Lead time:Sample in stock/bulk order depend on quantities | |
| Color temperature: 3000K/4000K/5000K/5700K/6500K |
Natatorium lights are designed for indoor swimming pool. They have a special coating that allows them to operate in a swimming pool environment. These commercial indoor pool lights are designed to last a long time and require no maintenance.
The most common color temperature options for natatoriums are 4000K or 5000K. 5000K is a good alternative to metal halide fixtures. We offer both color options for our natatorium-grade commercial swimming pool lights.
All of the fixtures we list here meet or exceed IP65 ratings. The IP rating is a test of how well a fixture is protected from water and dust.

Swimming pool lighting fixtures are always exposed to high humidity, water and chlorine. Therefore the fixtures should be rated to withstand this environment.
Using PC lenses on our LED lights and using epoxy coating/powder coating protects the fixture from corrosion. The body of the LED light is cast aluminum, which performs very well in this environment. In addition, any fixture used should be rated IP65 or higher.
All MECREE natatorium-rated luminaires sport requirements of:
There are two ways to look at answering this question. If you have an existing Natatorium, then you may want to do a one-for-one replacement of your lights over to LED.
If you are looking for new lighting or new lighting locations, then creating a Natatorium Lighting Plan will help you determine light locations.
A lighting plan details light locations and provides foot candle readings at specific locations over the pool.
Yes they are. Our LED Lights can replace Metal Halide and provide you with a high quality long lasting lighting solution. Whether you are looking for ceiling mounted high bays, wall mounted flood lights, or retrofitting your up lights, we have the products and power to brighten any natatorium.
What is the beam angle?
Beam angle refers to the angle of the light source or lamp, that is, the angle formed by the boundary of a certain intensity range of the beam. Generally, the beam angle on the illuminated surface is directly reflected by the light spot and illumination. Under the same conditions, the larger the beam angle is, the smaller the central light intensity is, the larger the spot is, and the smaller the illumination is. Otherwise, the opposite is true.

Color temperature explains how warm or how cool the football lights look like throughout the human eye,and that’s expressed from the unit named Kelvin (K). It generally scales from 1000 to 10, 000 K. For the standards for the football stadiums, the overall color temperature need to be greater than 4,000 k for all classes. But, it’s suggested that cool white lights (from 5,000 K to 6,000 K) would be the most acceptable option since they’re more invigorating and provide much better lighting effect for players in addition to audiences.

Are you still worried about transportation? How to ship to your country?
Don’t worry, we provide express, air and sea services. For samples, we generally recommend express door-to-door service. For bulk orders, you can choose air or sea transportation according to the time of the project
If you have your own freight forwarding company, you can arrange your freight forwarder to pick up the goods at our factory.
We will draft a contract according to your payment request, we support bank transfer and credit card payment. After receiving the payment, we will arrange the order. After the goods are ready, we will arrange transportation, the courier will contact you before the goods are delivered.
Please keep the contract and warranty, you can contact your dedicated salesperson or directly contact our official website.
MECREE SPECIFICALLY DESIGNED PLC (PRECISE LIGHT CONTROL) TO MEET THE NEEDS OF SUCH USERS, POLARIZED LIGHT 73°DEFINED AS P73 SERIES PRODUCTS, P73 SERIES PRODUCTS TO BRING YOU AN UNPRECEDENTED VISUAL FEAST.
MECREE are not only a manufacturer of high-power LEDs, More professional services are also included:
1. According to the requirement to provide the best stadium lighting solutions, including horizontal, vertical illumination, uniformity, glare control, spill light control, energy saving.
2. About the design of lighting mast, Mecree according to the wind speed at the place can be used to calculate the axial force, bending force, horizontal shear force and torque for the construction engineer, so as to protect the users from unnecessary accidental.
3. One stop service for you! High power generator set supporting, and we also supply cables, switches, power distribution cabinet and other parts. We are your best supply chain manager!
4. Professional Lighting installation guide including to the circuit design service and installation angle guide of each lights.
Join MECREE! Save you time,unnecessary costs and greater benefits.