banner

Published by admin01 16,2019

Niigata Stadium

Niigata stadium Category: venue for international sporting events. Built in: March 2001. Size: 42,300 people. Architectural features: net frame structure, Teflon film covering 90% of the auditorium. The audience seats are double-decker, with a tilt of 31degree. Major games held: 2002 World Cup Japan division opening ceremony venue. Lighting mode: the mixed illumination of high color type light source and common light source can meet the requirement of high definition color TV. Light source: Short arc 2kw narrow angle instantaneous restarting projector 98 sets. Short arc 2kw medium angle instantaneous restarting projector 44 sets. Short arc 2kw narrow angle projector 20 sets. Short arc 1.5kw medium angle projector 48 sets. Short arc 1.5kw narrow angle projector 110 sets. Illumination index: average horizontal illumination 1590lux, average vertical illumination 1030lux. Comments: 320 sets floodlights, power consumption 561kw, average vertical illumination is only 1030lux, while FI...

Do you like ? 932

Read more

Published by admin01 14,2019

Montjuic Olympic Stadium, Barcelona

Brief Introduction Scale: Can accommodate more than 65,000 spectators and own 9400m runways. The large-scale sports meeting held: The main venue of the 25th Summer Olympic Games in 1992 (all track and field events, opening ceremony, closing ceremony), the marathon and the end of the race are also located here. Solution Lighting method: 5 tower + light belt. Lamp source: MVF406/MHDl800W, 454 sets. Lighting indicators: average horizontal illumination of l500lux. The average vertical illumination is 1 400 lux. Color temperature: 5600K. Color rendering index: Ra>90. Lighting method: For sports lighting, AOMSA (Municipal company managing the Olympics project) A small floodlight that can be installed on the edge of the ceiling and below is required. Five thin columns are used on the other side to illuminate the shadows on the front and other preset ranges. Montjuic officially chose Philips’ AV system to achieve their goals. The compact size and light weight of the AV ensure eff...

Do you like ? 749

Read more

Published by admin01 14,2019

Sydney International Aquatic Centre, Australia

Location: Sydney, Australia. Time of completion: l994. Use plan: This magnificent complex was opened in October 1994 to provide world-class competition and training facilities for all water sports, as well as recreational swimming pools. Large-scale Games: Swimming and Diving Competition in Sydney, Australia 2000 Olympic Games. Lamp light source: MVF406/MHDl800W: 327 sets of ordinary type and 28 sets of heat trigger type. HNF902/HPI-T2000W: 60 sets. Lighting Indicators: Color temperature: 5600K. Color rendering index: Ra > 90. Through Philips lighting design services, it has designed and provided a sophisticated lighting system. Before installing and building everything, integrated computer models and CAD models have been used to predict light intensity and glare hazards in specific directions of the camera. The original design plan (which began preparation in May 1992) was actually part of Sydney’s Olympic bid. The end result is a high-quality installation that serves au...

Do you like ? 746

Read more

Published by admin01 11,2019

Kashima Football Stadium

Kashima football stadium Category: professional football field. Completion date (reconstruction) : May 2001. Scale: 41,800 people (after reconstruction). Architectural features: suspended roof structure, Teflon film covering two-thirds of the auditorium. Major games held: 2002 World Cup. Lighting mode: before modification, vertical bar lighting is adopted, with relatively heavy shadows. After modification, eaves lighting is adopted, without obvious shadows. Illumination index: average horizontal illumination 1500lux. Average vertical illumination 1230lux. Mecree 800-1000w floodlights can directly replace the 2000w MH lamps in the stadium. Suppose replacing the old lamps with our GL-FL-800w, based on the power consumption of 8 hours per day and 365 days per year, 800w LED floodlights can save 70% on electricity costs per year compared with 2000W MH lights. Conclusion Mecree provides high quality and durable LED lighting solutions can meet your different standard remands for footbal...

Do you like ? 795

Read more

Published by admin01 11,2019

Stade Velodrom, Marseille stadium

The build time: 13th June 1937 Address: The town centre of Marseille Scale: There were 42000 seats before modification There are 60000 seats after modification The major competition which was held: France Football World Cup in 1998, as shown in chart 7-32 and chart 7-35 Architect: Jean Pierre Buffi The layout of lights: The structure of stadium and geometric dimensioning limits the layout of lights strictly. The height of canopy on one side of a grandstand is about 30 m, this limits the layout to four towers, but the light pole is far from the filed. For comprehensive consideration, choosing the way of the mixed mode of light belt and two light pole lighting. There is a horse path on the roof of the bleachers. A total of 40 sets of lamps are installed on the two floors whose height respectively 31 m and 33 m. Two light poles with an average height of 51 m were set at the side of the open stand, the light pole were titled 20, each pole were installed 46 pcs lights. Model: MVF 406/ ...

Do you like ? 732

Read more

Published by admin01 11,2019

Miyagi Stadium

Category: The first category of track and field sports venues(both ball venues). Build Time: March 2000. Scale: About 50000 people. Architectural Features: Grid structure, metal roof, covering 2/3 of the auditorium, crescent-shaped girders from the ground frame to the highest level. The major competition which was held: 2002 World Cup soccer tournament; 2001 Miyagi Japan National Sports Conference main venue. Lux level: Average horizontal illumination is 1500lux. Average vertical illumination is 1280lux. Color rendering index: Ra=91 What is different between traditional lamp and LED light? Led light can reach the best lux requirement, and can rand save more cost. Mecree Led stadium light with high CRI80/90+, high light efficiency 160lm/w, it’s 4-5 times of traditional lamp. We use calculus optical lens, PC material (There are many company use PC material, but but it has the 1-6 times difference for the cost of PC.Bad one will cause high light decay of 80% in one year, but ours is ...

Do you like ? 856

Read more

Published by admin01 11,2019

Sapporo Stadium

Sapporo stadium Category: baseball field and football field. Completion date: May 2001. Size: 41,300 people at a baseball game; 42,300 people at the football game. Architectural features: the roof is a spherical metal roof, covering 100% of the auditorium. The baseball field and football field can be switched from one another. This is the first case in Japan. Major games held: 2002 World Cup in Japan. Lighting fixtures: Special light fixtures, prevent hard ball from hitting. For football field — 468 sets of 1.5kw long arc projectors (353 sets of narrow Angle lamps and 115 sets of middle Angle lamps). For baseball field — 630 sets of 1.5kw long arc projectors (442 sets of narrow Angle type and 118 sets of middle Angle type). Long arc 1.5kw projectors 42 sets — for vertical lighting of baseball field. Long arc 1.5kw projectors 48 sets — for audience lighting. Illumination index: average horizontal illumination 1550lux. Average vertical illumination 1200lux. C...

Do you like ? 765

Read more

Published by admin01 10,2019

Home’s stadium

Category: Stadium field, as shown of the following pictures The build time: October 2001 Scale: About 42000 people (Usually about 34000 people) The architectural feature: Net frame structure, metal roof, covering two thirds of the auditorium The major competition which was held: Football World Cup in 2002 Lights: 64 pcs 2000w narrow beam angle light 72 pcs 2000w middle beam angle light 64 pcs 1500w narrow beam angle light 72 pcs 1500w middle beam angel light Lux level: Average horizontal illumination: 1680 lux Average vertical illumination: 1220 lux Color Rendering Index: Ra=83 To reach the best lux requirement, how many pcs and watts of Mecree led can replace the above lights? How much cost will be saved for you? Mecree Led with high CRI>80, high light efficiency 160lm/w, it’s 4-5 times of traditional lamp. 64pcs 800 w+ 64 pcs 800w+ 64 pcs 600w + 72 pcs 600w It can save more than 80% energy and electricity . And you don’t need to worry about maintain it or replace it. Besides,...

Do you like ? 781

Read more

Published by admin01 10,2019

Gerland stadium (Stade de Gerland)

Build Time: In 1926. Site: District 7 of Lyon Architect: Albert Constantin Architectural Features: The Gerland Stadium is the venue for the two World Cup matches and is also a local historic building. The major competition which was held: 1998 France FIFA World Cup Scale: Before Transformation: 42000 seats After Transformation(In 1998): 44000 seats The layout of lights: Four towers, lighthouse height 40 meters Model: MVF 406/ MHD1800W 216pcs(One side, 58 sets per tower; one side, 50 sets per tower),including 164pcs CAT A3, 38pcs CAT A4, 14pcs CAT A5. Lux level: Average horizontal illumination is 2000 lux Average vertical illumination is 1600 lux Color Temperature: 5600 k Color Rendering Index: Ra>90 Comments: This is an excellent lighting design, using only 216pcs lamps, about 400KW energy consumption, reaching the average vertical illumination of 1600lux, which is worth studying by readers. Please note that the lighthouse of the four-corner lamp is asymmetrical, which is often...

Do you like ? 797

Read more

Published by admin01 10,2019

Korea Sangam stadium lighting design

Sangam stadium Seoul, Korea Completion date: December 2001 Location: Seoul, South Korea Architectural features: the roof of Seoul Sangam stadium with unique football concept can cover 93% of the entire auditorium area;The stadium’s exterior is a huge rectangle, like the shape of a traditional Korean kite;The pillars that hold up the roof resemble the masts of traditional Korean ships on the Angang river Scale: can hold 63930 audiences Major games held: 2002 football World Cup venue Light source of lamps: MVF403 / MHD2000W: 264 sets MVF024 / MHD – TD2000W: 36 sets QNF417/1500 w Halogen: 18 sets Lighting index: Average horizontal luminosity: 2000lux Average vertical luminosity: 1500lux CCT: 5600 k CRI: Ra>90 Comments: the huge ceiling covers the stadium, and its unique architectural shape makes the stadium can only be used in the way of light belt distribution, lamps and lanterns layout is more reasonable, 300 lamps and lanterns to achieve such a high level of lightin...

Do you like ? 891

Read more

Published by admin01 10,2019

Barcelona Sant Jordi stadium lighting design

Sant Jordi stadium in Barcelona Size: 17,000 seats Architect: Arata Isozaki (Japan) Architectural features: it has a 128mX106m race area and a large dome over 13000m2, 45m high from the track Major games held: venues for gymnastics, handball, and volleyball at the 25th summer Olympic Games in 1992 Lighting: level lighting, dome lighting, public area lighting and service area lighting Lamp source: HNF002/ HPI-T2000w : 240 sets Lighting index: Average horizontal luminosity : 2500lux Average vertical luminosity : 1250lux CCT: 5600 k CRI: Ra>90 Design concept: there are two main objectives to be achieved: first, centralized lighting of the competition area to save energy;Secondly, try to focus the audience’s attention on the ongoing activities as much as possible, so as to improve the visual comfort.For different sports areas, including 200m track, different levels of lighting were set according to their different needs.These requirements include: match and post-match, train...

Do you like ? 801

Read more

Published by admin01 09,2019

Australian National Stadium

Venue Basic Information Scale: It can accommodate 110,000 spectators, the height of the stadium: 58m, costing 650 million Australian dollars. The exterior and interior are shown in Figure 1-1 and Figure 1-2. Sports: track and field, football, assembly, performances, etc. The large-scale sports meeting held: the main venue of the 27th Summer Olympic Games in 2000 (all track and field events, opening ceremony, closing ceremony, football finals). Lighting method: Light belt + 4 tower type. Lamp source: PRT2000W, 542 sets Lighting indicators: Olympic lighting mode lighting parameters see Table 1-1 1-1 Name Lighting parameters Average of the illuminance of the four faces at 1.5 m on the ground Ev 1400 1800 1890 U1=Ev+min/Ev+max 0.40 0.60 0.62 U2=Ev+min/Ev+ave 0.60 0.80 0.78 Average of horizontal illuminance on the ground Ev 2000 2400 2500 U1=Eh+min/Eh+max 0.40 0.68 0.72 U2=Eh+min/Eh+ave 0.60 0.80 0.86 Illuminance gradient(%/5m) 20 14 – Ev+ave:Eh+ave 0.5-0.2 1....

Do you like ? 871

Read more

    Contact Us For Quote and Lighting Opinion

    Let's start design your lighting project.
    Please try to answer our following questions or call us.

    1. What kind of field you need to light up? Is a new court or need to replace the old lamps?

    2. If you need to replace the old lamps, what's your current lamps?

    3. What's the size of your lighting field? How many poles? What's the height of your poles?

    4. What's your lux request?

    5. What's the quantity you need?

    en English
    ar Arabiczh-CN Chinese (Simplified)nl Dutchen Englishfr Frenchde Germanit Italianpt Portugueseru Russianes Spanish
    // //