Do you want to a powerful supplier can provide a whole series service including solution, lights, cable, poles and so on?
Do you still worry the spillover light affect the surrounding of sports lighting?
Do you still worry will stadium lighting have a strong glare affecting the game?
Do you worry about a floodlight with a 4D radiator and the largest heat dissipation area in a high temperature outdoor environment?
Do you want to select the best stadium lights for tennis courts?
Do you want to save cost for a football field lighting project?
Soccer field lighting system is an important schedule to all the people .According to the regulations of FIFA, the length of the Soccer field is 105~110m, the width is 68~75m, and there should be no obstacle at least 5m outside the bottom line and the side line to ensure the safety of the athletes.
Soccer field lighting is divided into indoor soccer field lighting and outdoor soccer field lighting. Different lighting installation in different places. Standard according to the football field to use a function to determine the standard of illumination, Roughly is divided into four levels, training and recreation illumination 200 lx, amateur competitions 500 lx, professional game 750 lx, large international high-definition television 1400 lx.
Traditional lights is generally the metal halide lamp, and it has glare, energy-intensive, short lifespan, inconvenient installation, low CRI, the actual brightness is not enough and so on, so how to choose the suitable soccer field lights?
The standards of soccer field lighting system
| 1. Lighting standards for outdoor soccer field | |||||||||||
| Rank | Application | Illuminance( lx) | Lighting Uniformity | Lighting | |||||||
| Eh | Evmai | Uh | Uvmin | Uvax | Ra | CCT | |||||
| U1 | U2 | U1 | U2 | U1 | U2 | ||||||
| I | Training and recreation | 200 | ———– | —- | 0.3 | —- | —– | —— | —— | ≥20 | |
| II | Amateur competitions | 300 | ———– | —- | 0.5 | —- | —– | —— | —— | ≥80 | ≥4000 |
| III | Professional competition | 500 | ———– | 0.4 | 0.6 | —- | —– | —— | —— | ≥80 | ≥4000 |
| IV | International competition for HDTV broadcast | ———– | 1400 | 0.6 | 0.8 | 0.5 | 0.7 | 0.3 | 0.5 | ≥80 | ≥5500 |
| Attention: Avoid causing direct glare to players, especially to goalkeepers in corners | |||||||||||
| 2. Lighting standards for indoor soccer field | |||||||||||
| Rank | Application | Illuminance( lx) | Lighting Uniformity | Lighting | |||||||
| Eh | Evmai | Uh | Uvmin | Uvax | Ra | CCT | |||||
| U1 | U2 | U1 | U2 | U1 | U2 | ||||||
| I | Training and recreation | 300 | ———– | —- | 0.3 | —- | —– | —— | —— | ≥65 | |
| II | Amateur competitions | 500 | ———– | 0.4 | 0.6 | —- | —– | —— | —— | ≥65 | ≥4000 |
| III | Professional competition | 750 | ———– | 0.5 | 0.7 | —- | —– | 0.3 | 0.5 | ≥80 | ≥4000 |
| IV | International competition for HDTV broadcast | ———– | 1400 | 0.6 | 0.8 | 0.5 | 0.7 | 0.3 | 0.5 | ≥80 | ≥5500 |
| Attention: There should be adequate lighting on the field to avoid glare on the athletes | |||||||||||
Mecree Led has done many international stadium project including FIFA Word Cup Project, we can support the dialux simulation due to your project requirement, and deign the best lighting system to not only save your cost but also the high quality products or service.
1.Dimming system
We have 0-10V,1-10V, Dali, Dmx dimming models, fast and bright to adjusts real-time control.
2.Safe and low maintenance
No risk of explosion leakage, less spillage, low maintenance cost.
3.Calculations optical design, low glare, no any flickering, light decay<5% (within 5 years); 4D cooling system, junction temperature <65℃.
If you have any questions about the stadium project, please feel free to contact with Mecree.

Guangzhou, China – June 2026 – The 31st Guangzhou International Lighting Exhibition (GILE), one ...
MECREE sincerely invite you meet us on the Guangzhou International Lighting Exhibition, 9th-12th...