The center of a football pitch looks bright, but the corners remain in shadow. Players struggle to follow the ball near the sidelines, and cameras capture uneven scenes as the action moves across the field.
This is a common sports lighting problem: the average illuminance may look acceptable, while the light distribution across the playing area tells a different story. For stadium owners, contractors and lighting designers, achieving the required brightness is only part of the job. The light also needs to reach the right places with sufficient consistency.
Lighting uniformity provides a practical way to evaluate that consistency. Understanding U1 and U2 can help project teams identify dark areas, compare lighting designs and plan a more effective sports lighting system.
Table of Contents
Lighting uniformity describes how evenly illuminance is distributed across a defined area or reference plane. It is calculated using illuminance values at points on a specified calculation or measurement grid.
The UEFA Stadium Lighting Guide uses two ratios to assess uniformity: [1]
U1 compares the darkest and brightest grid points, while U2 compares the darkest point with the average. Both ratios range from 0 to 1; values closer to 1 indicate a more even distribution across the evaluated grid.
These ratios must be calculated using values from the same grid and reference plane. Different standards and project specifications may use different labels or evaluation methods, so always confirm the formula, grid and requirements before comparing reports.
Two lighting designs can have the same average illuminance but deliver very different results across a field. Consider the following simplified example:
| Measurement | Design A | Design B |
| Average illuminance | 600 lux | 600 lux |
| Minimum illuminance | 180 lux | 420 lux |
| Maximum illuminance | 1,000 lux | 800 lux |
| U1: minimum ÷ maximum | 0.18 | 0.525 |
| U2: minimum ÷ average | 0.30 | 0.70 |
Although both designs average 600 lux, Design B has a smaller difference between its brightest and darkest points. These values are illustrative, not a recommended target for every sport or venue.
Better uniformity can help players see the ball and field markings more consistently, support visual comfort and provide a more consistent lighting environment for cameras. Higher ratios alone do not guarantee a compliant or comfortable installation: illuminance levels, glare, vertical lighting and other applicable criteria still need to be checked.
Uneven lighting can result from several factors working together:
Adding more floodlights or increasing wattage without checking these factors may raise the average lux while leaving the underlying distribution problem unresolved.
Start with the sport, field dimensions, level of competition and intended use. A training facility, a professional match venue and a televised stadium may need different lighting conditions.
Identify the applicable standard or competition rules, including the required illuminance, uniformity ratios, evaluation grids and maintenance conditions. For broadcast projects, include camera positions, vertical illuminance and the requirements of the relevant broadcaster or event organizer.
Pole locations and mounting heights influence how effectively light reaches the center, sidelines and corners. A new venue may offer more flexibility, while a retrofit must account for existing structures, load capacity, obstructions and available mounting space.
Model the actual field dimensions and mounting positions before selecting a final layout. If restrictions make a target difficult to achieve, the project team can assess alternatives before installation begins.
Beam angle and light distribution matter as much as fixture output. Depending on the layout, a design may use different optics to reach distant areas and provide suitable coverage closer to the poles.
The goal is to coordinate the beams across the entire playing surface. Well-planned overlap can help reduce dark gaps and excessive hot spots while directing light where it is useful.
Photometric simulation helps the design team test a lighting arrangement before equipment is installed. Software such as DIALux, Relux or AGi32 can be used to evaluate a model of the venue using the selected luminaires’ photometric data.
A useful report should show the calculation grid, minimum, average and maximum illuminance, clearly defined uniformity ratios, fixture models, optics, mounting positions, aiming information and the maintenance factor. False-color plots can help locate weak areas, but the numerical results and evaluation conditions are needed to interpret them.
If the results reveal a dark corner or an overlit center, the designer can adjust fixture positions, optics, quantities or aiming and recalculate the whole field.
Improving uniformity should be considered alongside player and spectator comfort and the surrounding environment. Aiming a floodlight farther across a field may improve coverage, but its effect on glare and light outside the venue must also be assessed.
Sometimes an overlit area can be reduced while a darker area is improved. Any adjustment should be checked against the required minimum and average illuminance, as well as the other project criteria.
A simulation is a design tool; the installed system still needs to be checked. Fixture selection, mounting heights and aiming should follow the approved plan, and any site changes should be reviewed against the lighting calculations.
After installation, measure illuminance using the grid, instrument setup and procedure required by the applicable standard or project specification. Compare the results with the required values and document any necessary adjustments. Allowing a suitable design margin can help account for differences between calculated and measured results. [1]
Horizontal illuminance describes light falling on a horizontal plane, such as the playing surface. It is useful for evaluating how consistently the field itself is illuminated.
Vertical illuminance describes light falling on a vertical plane. It helps assess illumination of players and other subjects from specified directions and is particularly important for televised events.
For a broadcast venue, a field that looks evenly lit from above may still have uneven lighting on players from a camera’s viewpoint. The design should therefore check the required vertical planes and camera directions as well as the horizontal grid.
There is no single U1 or U2 value for every venue. Requirements depend on the sport, competition, governing body, lighting class and intended use.
For example, UEFA Stadium Lighting Guide 2023 Level B. These are selected requirements, not a complete project specification: [2]
| Evaluation | Average illuminance | U1 | U2 |
| Horizontal | At least 1,400 lux | Greater than 0.50 | Greater than 0.70 |
| Vertical, on each reference plane | At least 1,000 lux | Greater than 0.40 | Greater than 0.50 |
Other sports, competition levels and broadcasting requirements may use different criteria. Always verify the current rules for the specific event and venue.
A successful sports lighting project brings together more than floodlights. The field layout, optics, pole positions, aiming and on-site verification all influence the final result.
MECREE supports sports lighting projects with luminaire selection, photometric simulation, lighting controls, installation guidance and on-site aiming and calibration. Our team can help review the design against your project’s requirements and identify options for improving coverage across the playing area.
Planning a new venue or upgrading an existing field? Contact MECREE with your field dimensions, pole layout and lighting requirements to discuss a tailored solution.
1. UEFA Stadium Lighting Guide 2023, Uniformity
2. UEFA Stadium Infrastructure Regulations, Article 16 Floodlighting
For football venue operators, replacing metal halide floodlights with LED can reduce electricity ...
4000K and 5700K offer different white-light appearances, and the right choice depends on how a sp...